Re-roof Requirements

Roofing Requirements for Clear Creek County
Current Code edition: 2015 IRC and IBC

If decking is being replaced, must be inspected.

New roof must be Class A rated material or Class A rated assembly, must submit rating documentation.

Mid-roof inspection is required at the point that drip edge, other required flashing, underlayment, Ice barrier have been installed.

Telephone # 303-679-2333
Max # of layers Remove all layers
Mimiumum Wind Speed 100 MPH and 110 MPH
Re Roof W/Shakes? YES CLASS A RATED ASSEMBLY ONLY
Ice Barrier Yes (minimum 24" from exterior wall line)
Mid Roof Inspection? Yes
Ladder Required? Yes
High Wind Nail? Per Code
Drip Edge Required? Yes ( eave and rake)
Valley Size Minimum Per Code
Valleys Open / Closed / Both Per Code
Valley Material Required Metal/ 90 lb/ Either Per Code
Plywood Required Over Decking and Specs Per Code